order now
Home>Vibro meter>Vibro-Meter | CA202 144-202-000-205 | High-Temperature Piezoelectric Accelerometer
Vibro-Meter | CA202 144-202-000-205 | High-Temperature Piezoelectric Accelerometer

Vibro-Meter | CA202 144-202-000-205 | High-Temperature Piezoelectric Accelerometer

Item NO.: CA202 144-202-000-205

 if you need more details,you can scan below:

      

          Wechat                        Whatsapp

Detail

  • Product NameVibro-Meter | CA202 144-202-000-205 | High-Temperature Piezoelectric Accelerometer
  • Item NO.CA202 144-202-000-205
  • Weight0.0000 kg = 0.0000 lb = 0.0000 oz
  • CategoryVibro meter
  • BrandVibro meter
  • Creation Time2026-08-11
  • Vibro-Meter CA202 144-202-000-205 charge-output accelerometer. Official performance, 3 m legacy configuration, lifecycle status and current candidate alternative.
CA202 / TECHNICAL DOSSIEROFFICIAL-DATA REVIEW

CA202 144-202-000-205

Vibro-Meter CA202 Charge-Output Accelerometer
Vibro-Meter CA202 Charge-Output Accelerometer
The CA202 combines a hermetically welded stainless-steel body with wide-band charge output for vibration monitoring in elevated-temperature machinery environments.
Part number 144-202-000-205 is not listed in the current Version 10 ordering table. Its legacy position corresponds to the 3 m standard-cable configuration; the current document lists 144-202-000-206 for 3 m. Confirm interchangeability before purchase.
LIFECYCLE ANSWER

Legacy ordering number: Parker Meggitt does not publish a stop-production date for -205. The current documented 3 m candidate is 144-202-000-206; manufacturer approval is required before substitution.

Official source: Parker Meggitt / Vibro-Meter, CA202 Piezoelectric Accelerometer Data Sheet, Version 10 (2024-01-10). View official source

Laboratory Reference Parameters

Sensor type Charge-output, two-wire piezoelectric accelerometer
Sensitivity 100 pC/g ±5% at 120 Hz
Dynamic measuring range 0.01 to 400 g peak
Overload capability 500 g peak
Frequency response 0.5 to 6000 Hz, ±5%
Resonant frequency >22 kHz nominal
Sensor temperature range -55 to +260 °C
Integral cable temperature -55 to +200 °C
Construction Austenitic stainless steel; hermetically welded
Approximate weight Sensor 250 g; integral cable 135 g/m
Signal conditioning IPC70x charge amplifier required

Other Available Part Numbers

Part number Part number
VKG20700 3RX9501-0BA00
4058001DC1-S ABM205-1-S
S286-1A/T6 TA4207SCA
545-0BB15-2AX0 C143-35T
PROC20K 0348M-070-02D-004
NXL00032C1N1SSS00 N-A1FDC
88VT02A-E 01-0030-3+D150+E200+L501+L502+L503
PLGE050H L1S160S-0833-00-00-003
Q68ADV SC-N6
PFRL101B-1.0KN DI840
23124-E1A-M M04HP342740
NM053-01L06B XC-ES30CE
U-S060

Part-number list is for reference; confirm current availability when requesting a quotation.

Where This Product Fits

Maintenance replacement
Match the full code and existing system before replacing installed hardware.
Project procurement
Confirm quantity, destination, required date and documentation needs.
Engineering review
Check compatibility, approvals, mounting and environmental conditions.

What to Include With Your Enquiry

CA202 144-202-000-205
Required quantity and delivery destination
Existing nameplate photo or system details, when available
Condition, warranty and documentation requirements
Whether a technically suitable alternative may be considered

CA202 144-202-000-205 Product FAQ

Practical ordering, engineering, lifecycle and replacement answers based on official product documentation.

What is CA202 144-202-000-205 used for?

CA202 144-202-000-205 is Vibro-Meter CA202 Charge-Output Accelerometer. The CA202 combines a hermetically welded stainless-steel body with wide-band charge output for vibration monitoring in elevated-temperature machinery environments.

Which technical details should an engineer verify for CA202 144-202-000-205?

Verify the complete ordering code plus installation, system-compatibility and approval requirements. Key official data includes Sensor type: Charge-output, two-wire piezoelectric accelerometer; Sensitivity: 100 pC/g ±5% at 120 Hz; Dynamic measuring range: 0.01 to 400 g peak.

What should a distributor or reseller provide for a CA202 144-202-000-205 quotation?

Provide the complete part number, quantity, delivery destination, requested date and the existing nameplate or system information when available. This helps confirm price, availability, condition, warranty and lead time.

Is CA202 144-202-000-205 discontinued, and is there a replacement?

Legacy ordering number: Parker Meggitt does not publish a stop-production date for -205. The current documented 3 m candidate is 144-202-000-206; manufacturer approval is required before substitution.

Can an end user replace an installed unit with a similar model?

Do not substitute on appearance alone. Compare the complete ordering code, system compatibility, physical configuration, approvals and environmental requirements. Part number 144-202-000-205 is not listed in the current Version 10 ordering table. Its legacy position corresponds to the 3 m standard-cable configuration; the current document lists 144-202-000-206 for 3 m. Confirm interchangeability before purchase.

How can I request price and availability for CA202 144-202-000-205?

Use the WhatsApp or email link on this page and include CA202 144-202-000-205, quantity and delivery destination. The enquiry subject is prepared automatically for this product.

Request a quotation for CA202 144-202-000-205
Add: 32D Guomao Building, Hubin South Road, Siming District, Xiamen, Fujian, China
Quote CA202 144-202-000-205
+86-18106909650 ✉sales8@apterpower.com

You May Also Like